Description of Hearing Loss​
Flat  - </= 5 dB per octave
Gradual  -  6 - 10 dB per octave
Steep  -  11 - 15 dB per octave
​Preciptious . -  > 16 dB per octave
Asymmetric Criteria
>/= 15 dB at one frequency
>/= 10 dB difference at 3 separate frequencies

Test-Retest Reliability / Significant Δ
> 10 dB Δ is significant
</= 10 dB test-retest reliability
Severity of Hearing Loss
Adults
0-20 Normal
21-25 Slight Borderline/Normal
26-40 Mild
41-55 Moderate
56-70 Moderately Severe
71-90 Severe
>/= 91 Profound
Pediatrics
0-15 Normal
16-20 Slight
21-40 Mild
41-55 Moderate
56-70 Moderately-Severe
71-90 Severe
>/= 91 Profound
Word Recognition Test Presentation (based on 2kHz)
2 kHz = < 50 dB HL = +25dB SL
2 kHz = 50 - 55 dB HL = +20 dB SL
2 kHz = 60 - 65 dB HL = +15 dB SL
2 kHz = 70 - 75 dB HL = +10 dB SL 
2 kHz = >/= 80 dB HL = UCL - 5 dB HL

Word Recognition Scoring
NU-6 Word List Ordered by difficulty
94 - 100% . Excellent
80 - 93%  Good
70 - 79%  Fair
50 - 69%  Poor
<50%  Very Poor
0-1 Incorrect  Complete 10 Word List
2-3 Incorrect Complete 25 Word List
4+ Incorrect Complete 50 Word List
DPOAEs
Present  >/= 90th for adults >/= 95th for peds
Reduced 90th > X >/= 10th
Absent < 10th
Additional Info: Must be 6dB noise floor and repeatable

Tympanograms Normal Ranges: Adults 226Hz
Compliance - 0.3 - 1.5ml
Pressure - -150 - +50 daPa
Volume with PE tube - Volume should be at least double post PE tube placement
Morphology - use "rounded when applicable
Acoustic Reflexes
​